The Unexpected Ring: Our Surgical Technique for IOL–CTR Complex Removal
Purpose: To describe a simple technique for identifying and removing a concealed capsular tension ring (CTR) during dislocated IOL explantation. Methods: Two eyes with traumatic/dislocated IOLs were managed. Intraoperatively, a hidden CTR was identified during IOL removal. An iris repositor was used as a lever to apply a push–pull vector and flatten the CTR arch, facilitating its grasping and removal with straight forceps. Results: The concealed CTR was successfully removed in both cases without complications(retinal tear/Dialysis) Using an iris repositor as a vector. Iris repositor counterforce flattened CTR arch, thereby removed with ease. Visual acuity improved from counting fingers to 6/18 in the first case and to 6/9 in the second case. Conclusion: A concealed CTR should be anticipated during dislocated IOL removal, particularly in traumatic and referred cases. Our iris-repositor-assisted vector technique allows controlled flattening and facilitates safe IOL–CTR complex removal.