Adding Tissue, losing power: The DSAEK Paradox
DSAEK produces a paradoxical hyperopic shift of +0.5 to +1.5 D despite adding tissue to thicken the cornea. This educational video reveals the optical mechanism through thick lens analysis. The meniscus-shaped donor lenticule—thinner centrally, thicker peripherally—functions as a negative lens within the corneal system, contributing -1.0 to -1.5 D. Although posterior corneal flattening alone would cause myopic shift (+0.5 D), the dominant meniscus lens effect overcomes this, reducing total corneal power from +42 to +41 D. Using 3D animations, clinical OCT imaging, and quantitative optical modeling, we demonstrate why graft geometry, not thickness, determines refractive outcome. This mechanism explains the clinical correlation between graft thickness and hyperopic shift magnitude, with critical implications for IOL power calculation in combined cataract-DSAEK procedures and the reduced refractive changes observed with ultrathin DSAEK grafts.