For full functionality of this site it is necessary to enable JavaScript. Here are the instructions how to enable JavaScript in your web browser.

Scientific Program

FP398

1785

Dr.Kirthi Raj
Membership No Author Name Email Mobile
4742MW Dr.Arpita patil arpitapatil7474@gmail.com 9483787474
Cornea, Ocular Surface and External Eye Diseases

MINIMAL FIXATION, MAXIMUM STABILITY?? A COMPARATIVE STUDY OF AUTOGRAFT FIXATION IN PRIMARY PTERYGIUM

Purpose: To determine whether adding a single anchoring suture to autologous blood fixation can improve graft stability and comfort over conventional suturing and autologous blood fixation alone in primary pterygium.
Methods: A prospective randomized comparative study of 45 eyes(15/group) with primary pterygium, underwent autograft fixation by single anchoring suture-assisted autologous blood, conventional suturing and autologous blood alone. Operative time, postoperative comfort, graft stability and patient satisfaction were assessed.
Results: The anchoring group had shorter operative time (p<0.001) lower discomfort, graft stability comparable to conventional suturing (100% at Month 1) superior stability to autologous blood fixation, and the highest patient satisfaction (p<0.05).
conclusion: Single anchoring suture-assisted autologous blood fixation offered a balanced approach by combining the stability of conventional suturing with the comfort advantages of autologous blood fixation.

No Co-Author Selected