For full functionality of this site it is necessary to enable JavaScript. Here are the instructions how to enable JavaScript in your web browser.

Scientific Program

FP376

4724MW

Dr.Shwetha H
Membership No Author Name Email Mobile
4724MW Dr.Shwetha H shwethahreddy@gmail.com 7204623843
Refractive Surgery

MEM Dynamic Retinoscopy: Accommodative Response in Emmetropes and Refractive Errors

Purpose:This study evaluated accommodative response using Monocular Estimation Method retinoscopy in emmetropes and individuals with refractive errors.
Methods:In this hospital based cross-sectional study,100 participants aged 18–35 years were divided into emmetropes,myopes,hyperopes,and astigmats(n=25 each).Accommodative response was measured using MEM dynamic retinoscopy at 40 cm.Data were analyzed using Statistical software SPSS.26
Results:Mean accommodative lag differed significantly among groups(p<0.001),being highest in hyperopes(0.86±0.20 D) and lowest in emmetropes(0.43±0.15 D).Increased lag(>0.75 D)was most frequent in hyperopes(60%)(p=0.007). Accommodative lag correlated positively with spherical equivalent(r=0.52, p<0.001),while hyperopia,myopia,and spherical equivalent independently predicted higher lag.
Conclusion:MEM dynamic retinoscopy is a simple,reliable objective method for assessing accommodative function,with hyperopes demonstrating the greatest accommodative lag.

Membership No Author Name Email Mobile
1184 Dr.Rekha K R rekha.k.rathnaiah@gmail.com 9343530935