Correlation of Central Corneal Thickness with IOP Measured Using GAT and Tono-Pen in Normal Eyes

Purpose: To evaluate the correlation between central corneal thickness (CCT) and intraocular pressure (IOP) measured using Goldmann Applanation Tonometry (GAT) and Tono-Pen in normal eyes.

Methods: This hospital-based study included 50 healthy subjects. CCT was measured using ultrasound pachymetry, and IOP was recorded using GAT and Tono-Pen. Correlation and agreement between CCT and IOP measurements were analyzed using the intraclass correlation coefficient.

Results: 59 eyes were analyzed. Mean CCT was 538.4 ± 31.7 μm. Mean IOP by GAT was 14.7 ± 2.6 mmHg, while mean IOP by Tono-Pen was 14.9 ± 2.8 mmHg. CCT correlated with GAT (r=0.46, p=0.001) and Tono-Pen (r=0.49, p<0.001). GAT and Tono-Pen showed excellent agreement (ICC=0.91; 95% CI:0.85–0.95; p<0.001).

Conclusion: CCT significantly influences IOP measurements in normal eyes. Tono-Pen demonstrated good reliability as an alternative to GAT, highlighting the importance of considering CCT while interpreting IOP measurements.