Cataract

Intraoperative OCT Assessment of IOL– Capsular bag contact After CTR Implantation

Purpose
To evaluate the effect of capsular tension ring (CTR) implantation on intraocular lens (IOL) tilt, decentration, and posterior capsule apposition using intraoperative and anterior segment optical coherence tomography (AS-OCT)
Methods
In this prospective study, 251 eyes underwent phacoemulsification. Intraoperative spectral-domain OCT (Rescan 700) was performed in 51 eyes to measure IOL–posterior capsule distance before and after implantation of 11, 12, and 13-mm CTRs. Postoperative AS-OCT was performed in 200 eyes (100 CTR, 100 non-CTR) to assess horizontal and vertical IOL tilt and decentration
Results
CTR implantation significantly reduced IOL–posterior capsule distance (p<0.001), with the greatest reduction using 13-mm CTRs. There was no significant change in IOL tilt and decentration in eyes implanted with CTR
Conclusion
CTR implantation improves IOL- posterior capsule apposition intraoperatively, with no statistically significant difference in IOL tilt and decentration