Impact of Phaco Tip Exposure on Corneal Thickness and Endothelium in Hard Cataracts

Purpose: To evaluate phaco tip exposure on endothelial cell loss and central corneal thickness (CCT) in hard cataracts, comparing long versus short tip exposure.

Methods: Prospective randomised study of 114 eyes with hard cataract (LOCS III, grade 3+). Group 1 (n=57): short tip exposure (0.5mm); Group 2 (n=57): long tip exposure (1.25mm). CDE, CCT and endothelial cell density (specular microscopy) were assessed preoperatively, POD-1 and POD-30.

Results: CDE was significantly lower with the short tip (9.44 vs 12.96, p=0.008). CCT rise on POD-1 was lower with short tip (14.0 vs 40.0 microns, p<0.001); POD-30 difference was insignificant (p=0.74). Endothelial cell loss was significantly less with a short tip at POD-1 (-51 vs -183, p=0.003) and POD-30 (-135 vs -443, p=0.004).

Conclusion: Reduced tip exposure significantly lowered corneal edema and endothelial cell loss, underscoring tip exposure as a key modifiable variable in phaco technique for hard cataracts.